EGV HYP explosion vent - For zero to low negative pressure applications

 

Applications

The EGV HYP was specifically designed for hygienically demanding systems in the food and pharmaceutical industry, and is often utilized in critical systems such as spray and fluidbed dryers.

The special feature: The patented, full-flat, chamfered gasket system has a flush internal sealing area with the vent panel, and facilitates the avoidance of cross-contaminations.

The EGV Hyp explosion vent can also be pre-bent to conform to cylindrical vessels.

Explosion vent / panel EGV HYP for hygienic applications
REMBE® EGV HYP explosion vent

Mechanism

In the event of a sudden pressure increase, the EGV HYP vent panel will open and release the pressure from the vessel 

Your advantages

  • Hygienic design ensures consistently high quality of product.
  • Protects against cross-contamination when changing products.
  • Enables CIP cleaning.
  • Increased service life of the vent panel under alternating temperature and pressure stresses with the integrated bionic structure.
  • Reduces sound emissions (e.g. from hammers) at the venting channels.

Vent panels for hygienically demanding processes

With the EGV HYP and ERO vent panels are designed to meet production facilities' elevated hygienic requirements.

Certification

ATEX
EC type examination certificate no.
FSA 04 ATEX 1538 X 
SIL equivalent: SIL 4

 

Images

Explosion vent / panel EGV HYP for hygienic applications
REMBE® EGV HYP explosion vent
Detail gasket Explosion vent / panel EGV HYP
REMBE® EGV HYP explosion vent
Isolation Explosion vent / panel EGV HYP with signaling device SK
REMBE® EGV HYP explosion vent with Signaling Unit
Explosion vent / panel EGV HYP with isolation and signaling device SK
REMBE® EGV HYP explosion vent with Isolation and Signaling Unit
 
 

You can find appropriate signaling devices and other accessories here

contact us